Description
Detail
Power base, TeSys U, 12A, 110…220 V DC screw clamps control. range: TeSys – product name: TeSys U – device short name: LU2B – product or component type: reversing power base – device application: motor – poles description: 3P – suitability for isolation: yes – [Ith] conventional free air thermal current: 12 A – utilisation category: AC-41, AC-43, AC-44 – [Uc] control circuit voltage: 110…220 V DC, 110…240 V AC 50/60 Hz.
- · Height: 224mm
- · Range: Tesys U
- · Width: 45mm
- · Weight: 1.27kg
- · Depth: 126mm
Specification
With short-circuit release : Yes
Supporting protocol for INTERBUS : No
Supporting protocol for LON : No
Supporting protocol for TCP/IP : No
Supporting protocol for SUCONET : No
Suitable for emergency stop : No
Supporting protocol for MODBUS : No
Supporting protocol for other bus systems : No
Supporting protocol for Data-Highway : No
Supporting protocol for DeviceNet : No
External reset possible : No
Supporting protocol for SERCOS : No
Rail mounting possible : Yes
Supporting protocol for CAN : No
Supporting protocol for PROFINET CBA : No
Supporting protocol for Foundation Fieldbus : No
Supporting protocol for EtherNet/IP : No
Supporting protocol for INTERBUS-Safety : No
With fuse : No
Supporting protocol for DeviceNet Safety : No
Supporting protocol for SafetyBUS p : No
Supporting protocol for PROFINET IO : No
Supporting protocol for PROFIsafe : No
Supporting protocol for AS-Interface Safety at Work : No
Temperature compensated overload protection : Yes
Rated operation current at AC-3, 400 V : 12 A
Type of electrical connection of main circuit : Screw connection
Type of electrical connection for auxiliary- and control current circuit : Screw connection
Voltage type for actuating : AC/DC
Kind of motor starter : Reversing starter
Rated operation current Ie : 12 A
Number of auxiliary contacts as normally closed contact : 1
Number of auxiliary contacts as normally open contact : 1
Depth : 126 mm
Number of command positions : 3
Height : 224 mm
Rated operation power at AC-3, 400 V : 5.5 kW
Degree of protection (IP) : IP20
Rated conditional short-circuit current, type 2, 400 V : 50 A
Width : 45 mm
Rated conditional short-circuit current, type 2, 230 V : 50 A
Ambient temperature, upper operating limit : 70 °C
Number of indicator lights : 0
Rated control supply voltage Us at AC 60HZ : 110 – 240 V
Rated control supply voltage Us at DC : 110 – 220 V
Rated control supply voltage Us at AC 50HZ : 110 – 240 V
Supporting protocol for ASI : No
With transformer : No
Supporting protocol for PROFIBUS : No