TeSys LG, enclosed DOL starter, 2,5…4A, 220/230 V AC coil

£588.91 inc VAT £490.76 ex VAT

Description

Detail

TeSys LG, enclosed DOL starter, 2,5…4A, 220/230 V AC coil. range: TeSys – product name: TeSys LG – device short name: LG7K – device application: safety – utilisation category: AC-3 – device composition: circuit-breaker, contactor – motor power kW: 0.75 kW at 220/230 V AC 50/60 Hz, 1.5 kW at 400/415 V AC 50/60 Hz, 1.5 kW at 440 V AC 50/60 Hz – control type: mushroom head push-button emergency stop red, push-button start white I, push-button stop black O.

Specification

  • Supporting protocol for INTERBUS-Safety : No
  • Supporting protocol for PROFIBUS : No
  • Supporting protocol for CAN : No
  • Supporting protocol for Data-Highway : No
  • Supporting protocol for MODBUS : No
  • Supporting protocol for INTERBUS : No
  • External reset possible : No
  • Supporting protocol for DeviceNet : No
  • Supporting protocol for SUCONET : No
  • With short-circuit release : Yes
  • Supporting protocol for other bus systems : No
  • Suitable for emergency stop : Yes
  • Supporting protocol for DeviceNet Safety : No
  • Supporting protocol for TCP/IP : No
  • Rail mounting possible : No
  • Supporting protocol for Foundation Fieldbus : No
  • Supporting protocol for AS-Interface Safety at Work : No
  • Supporting protocol for EtherNet/IP : No
  • Supporting protocol for SERCOS : No
  • Supporting protocol for SafetyBUS p : No
  • Supporting protocol for PROFINET CBA : No
  • Supporting protocol for PROFINET IO : No
  • Supporting protocol for PROFIsafe : No
  • With fuse : No
  • Temperature compensated overload protection : Yes
  • Rated operation current Ie : 4 A
  • Degree of protection (IP) : IP55
  • Type of electrical connection for auxiliary- and control current circuit : Screw connection
  • Voltage type for actuating : AC
  • Kind of motor starter : Direct starter
  • Release class : CLASS 10
  • Number of auxiliary contacts as normally open contact : 0
  • Height : 165 mm
  • Width : 175 mm
  • Depth : 177 mm
  • Rated operation power at AC-3, 400 V : 1.5 kW
  • Rated operation power at AC-3, 230 V, 3-phase : 0.75 kW
  • Type of electrical connection of main circuit : Screw connection
  • Ambient temperature, upper operating limit : 40 °C
  • Number of command positions : 2
  • Rated operation current at AC-3, 400 V : 4 A
  • Number of indicator lights : 0
  • Rated control supply voltage Us at AC 60HZ : 220 – 230 V
  • Number of auxiliary contacts as normally closed contact : 0
  • Rated control supply voltage Us at AC 50HZ : 220 – 230 V
  • Overload release current setting : 2.5 – 4 A
  • Supporting protocol for ASI : No
  • With transformer : No
  • Supporting protocol for LON : No