Pressure switch XMLA 160 bar, fixed scale 1 threshold, 1 C/O

£367.99 inc VAT £306.66 ex VAT

SKU: 2500664762 Category: Tags: , ,

Description

Detail

Pressure switch XMLA 160 bar, fixed scale 1 threshold, 1 C/O. range of product: OsiSense XM – product or component type: electromechanical pressure sensor – device short name: XMLA – pressure sensor size: 160 bar – controlled fluid: air (0…160 °C), corrosive fluid (0…160 °C) – electrical connection: 1 connector Pg 13, screw-clamps terminals 1 x 0.5…2 x 2.5 mm² – AWG gauge: AWG 20…AWG 14 – product specific application: – – electrical circuit type: control circuit – scale type: fixed differential – local display: with – adjustable range of switching point on rising pressure: 10…160 bar – adjustable range of switching point on falling pressure: 4.5…142 bar – maximum permissible accidental pressure: 360 bar – destruction pressure: 720 bar – pressure actuator: piston – materials in contact with fluid: 316L stainless steel, FPM, FKM, PTFE – enclosure material: zinc alloy – [In] rated current: 0.1 A, R300, DC-13 (Ue = 250 V) conforming to EN/IEC 60947-5-1, 1.5 A, B300, AC-15 (Ue = 240 V) conforming to EN/IEC 60947-5-1, 3 A, B300, AC-15 (Ue = 120 V) conforming to EN/IEC 60947-5-1.

Specification

  • Medium temperature : 0 – 160 °C
  • Rated voltage Ue at AC 60 Hz : 120 – 240 V
  • Initial setting : 10000 – 160000 hPa
  • Engaging pressure : 10 – 160 bar
  • End setting : 4500 – 142000 hPa
  • Rated voltage Ue at AC 50 Hz : 120 – 240 V
  • Rated voltage Ue at DC : 250 – 250 V
  • Adjustable current range : 0 – 0 A
  • Switch off pressure : 4.5 – 142 bar
  • Max. operation pressure : 200000 hPa
  • With manual on/off switch : No
  • Explosion-proof : No
  • Electronic version : No
  • Suitable as 2-point controller : No
  • With hand operation : No
  • Suitable as limiter : Yes
  • Suitable as guard : Yes
  • Type of electric connection : Screw connection
  • Switching capacity at AC-3, 240 V : 0 kA
  • Rated operation current Ie at AC-3, 400 V : 0 A
  • Rated operation power at AC-3, 400 V : 0 kW
  • Number of auxiliary contacts as normally closed contact : 0
  • Rated operation current Ie at AC-1, 400 V : 0 A
  • Number of normally closed contacts as main contact : 0
  • End value measuring range pressure : 0 Pa
  • Number of main contacts as normally open contact : 0
  • Number of auxiliary contacts as normally open contact : 0
  • Bursting pressure : 720 bar
  • Initial value measuring range pressure : 0 Pa
  • Max. test pressure : 360 bar
  • Pressure-switching differential : 18 bar
  • Degree of protection (IP) : IP66
  • Number of auxiliary contacts as change-over contact : 1