TeSys D contactor, 3p(3 NO), AC-3, <= 440 V 65A, 230 V AC 50/60 Hz coi
£460.21 inc VAT £383.51 ex VAT
Description
Detail
TeSys D contactor, 3p(3 NO), AC-3, <= 440 V 65A, 230 V AC 50/60 Hz coil. range: TeSys – product name: TeSys D – product or component type: contactor – device short name: LC1D – contactor application: motor control, resistive load – utilisation category: AC-1, AC-3, AC-4 – poles description: 3P – pole contact composition: 3 NO – [Ue] rated operational voltage: <= 300 V DC for power circuit, <= 690 V AC 25…400 Hz for power circuit – [Ie] rated operational current: 65 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit, 80 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit – motor power kW: 11 kW at 400 V AC 50/60 Hz AC-4, 18.5 kW at 220…230 V AC 50/60 Hz AC-3, 30 kW at 380…400 V AC 50/60 Hz AC-3, 37 kW at 500 V AC 50/60 Hz AC-3, 37 kW at 660…690 V AC 50/60 Hz AC-3 – motor power hp: 10 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 20 hp at 200/208 V AC 50/60 Hz for 3 phases motors, 20 hp at 230/240 V AC 50/60 Hz for 3 phases motors, 40 hp at 460/480 V AC 50/60 Hz for 3 phases motors, 5 hp at 115 V AC 50/60 Hz for 1 phase motors, 50 hp at 575/600 V AC 50/60 Hz for 3 phases motors – auxiliary contact composition: 1 NO + 1 NC – overvoltage category: III – [Ith] conventional free air thermal current: 10 A at <= 60 °C for signalling circuit, 80 A at <= 60 °C for power circuit – Irms rated making capacity: 1000 A at 440 V for power circuit conforming to IEC 60947, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1 – [Icw] rated short-time withstand current: 100 A 1 s signalling circuit, 110 A <= 40 °C 10 min power circuit, 120 A 500 ms signalling circuit, 140 A 100 ms signalling circuit, 260 A <= 40 °C 1 min power circuit, 520 A <= 40 °C 10 s power circuit, 900 A <= 40 °C 1 s power circuit – associated fuse rating: 10 A gG for signalling circuit conforming to IEC 60947-5-1, 125 A gG at <= 690 V coordination type 1 for power circuit, 125 A gG at <= 690 V coordination type 2 for power circuit – [Ui] rated insulation voltage: 600 V for power circuit certifications CSA, 600 V for power circuit certifications UL, 600 V for signalling circuit certifications CSA, 600 V for signalling circuit certifications UL, 690 V for power circuit conforming to IEC 60947-4-1, 690 V for signalling circuit conforming to IEC 60947-1 – electrical durability: 1.4 Mcycles 80 A AC-1 at Ue <= 440 V, 1.45 Mcycles 65 A AC-3 at Ue <= 440 V – power dissipation per pole: 6.3 W AC-3, 9.6 W AC-1 – protective cover: with – mounting support: plate, rail – standards: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508 – product certifications: CCC, CSA, GOST, UL – connections – terminals: control circuit : lugs-ring terminals – external diameter: 8 mm, power circuit : lugs-ring terminals – external diameter: 16.5 mm – tightening torque: control circuit : 1.7 N.m – on lugs-ring terminals – with screwdriver flat Ø 6 mm screw : M3.5, control circuit : 1.7 N.m – on lugs-ring terminals – with screwdriver Philips No 2 screw : M3.5, power circuit : 6 N.m – on lugs-ring terminals hexagonal 10 mm screw : M6 – operating time: 12…26 ms closing, 4…19 ms opening – safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 – mechanical durability: 6 Mcycles.