TeSys LE, enclosed DOL starter, 8…11,5A, 240 V AC coil

£228.16 inc VAT £190.13 ex VAT

Description

Detail

TeSys LE, enclosed DOL starter, 8…11,5A, 240 V AC coil. range: TeSys – product name: TeSys LE – device short name: LE1M – device application: standard – utilisation category: AC-3 – device composition: contactor, earth terminal, neutral terminal, thermal overload relay – motor power kW: 2.2 kW at 220/230 V AC 50/60 Hz, 2.2 kW at 240 V AC 50/60 Hz, 4 kW at 380/400 V AC 50/60 Hz, 4 kW at 415 V AC 50/60 Hz – control type: push-button start green I, push-button stop/reset red O.

Specification

  • Supporting protocol for DeviceNet Safety : No
  • Supporting protocol for LON : No
  • Supporting protocol for SUCONET : No
  • Supporting protocol for PROFIBUS : No
  • Supporting protocol for TCP/IP : No
  • Supporting protocol for CAN : No
  • Supporting protocol for INTERBUS : No
  • Supporting protocol for Data-Highway : No
  • Suitable for emergency stop : No
  • External reset possible : No
  • With short-circuit release : No
  • Supporting protocol for other bus systems : No
  • Supporting protocol for INTERBUS-Safety : No
  • Supporting protocol for DeviceNet : No
  • Supporting protocol for PROFINET CBA : No
  • Supporting protocol for Foundation Fieldbus : No
  • Supporting protocol for SERCOS : No
  • Supporting protocol for AS-Interface Safety at Work : No
  • Supporting protocol for EtherNet/IP : No
  • Rail mounting possible : No
  • Supporting protocol for PROFINET IO : No
  • Supporting protocol for PROFIsafe : No
  • Supporting protocol for SafetyBUS p : No
  • With fuse : No
  • Temperature compensated overload protection : Yes
  • Ambient temperature, upper operating limit : 40 °C
  • Kind of motor starter : Direct starter
  • Degree of protection (IP) : IP65
  • Type of electrical connection for auxiliary- and control current circuit : Screw connection
  • Release class : CLASS 10 A
  • Voltage type for actuating : AC
  • Number of command positions : 1
  • Height : 160 mm
  • Rated operation current Ie : 11.5 A
  • Depth : 108 mm
  • Rated operation current at AC-3, 400 V : 11.5 A
  • Rated operation power at AC-3, 400 V : 4 kW
  • Type of electrical connection of main circuit : Screw connection
  • Width : 78 mm
  • Number of indicator lights : 0
  • Number of auxiliary contacts as normally closed contact : 0
  • Number of auxiliary contacts as normally open contact : 0
  • Rated control supply voltage Us at AC 50HZ : 240 – 240 V
  • Rated operation power at AC-3, 230 V, 3-phase : 2.2 kW
  • Overload release current setting : 8 – 11.5 A
  • Rated control supply voltage Us at AC 60HZ : 240 – 240 V
  • With transformer : No
  • Supporting protocol for ASI : No
  • Supporting protocol for MODBUS : No