Inductive sensor XS1 M8, L42mm, brass, Sn2mm, 12..24VDC, M8

£104.95 inc VAT £87.46 ex VAT

Description

Detail

Inductive sensor XS1 M8, L42mm, brass, Sn2mm, 12..24VDC, M8. range of product: OsiSense XS – series name: general purpose – sensor type: inductive proximity sensor – device application: – – sensor name: XS1 – sensor design: cylindrical M8 – size: 42 mm – body type: fixed – material: metal – type of output signal: discrete – wiring technique: 3-wire – output circuit type: DC – IP degree of protection: IP65 conforming to IEC 60529, IP67 conforming to IEC 60529.

  • · This XS cylindrical (M8 thread) inductive proximity sensor has a PPS sensing face and a nickel plated brass case.
  • · It has a supply voltage of 12V to 24V DC.
  • · This general purpose threaded cylindrical inductive proximity sensor is flush mountable and has an increased sensing range.
  • · It is mountable directly on a surface or bracket, thanks to its outer thread and twin nuts.
  • · High corrosion and impact-resistant nickel plating, keeping aspect and performance of the sensor for a longer time.

Specification

  • Max. output current at protected output : 200 mA
  • Switching frequency : 2500 Hz
  • Length of sensor : 42 mm
  • Diameter sensor : 8 mm
  • Width sensor : 0 mm
  • Number of protected contact energized outputs : 0
  • Switching distance : 2.5 mm
  • Number of contact energized outputs with signalling function : 0
  • Height of sensor : 0 mm
  • Number of protected semiconductor outputs : 1
  • Rated control supply voltage Us at AC 50HZ : 0 – 0 V
  • Rated control supply voltage Us at AC 60HZ : 0 – 0 V
  • Rated control supply voltage Us at DC : 12 – 24 V
  • Supply voltage : 12 – 24 V
  • Suitable for safety functions : No
  • Cascadable : No
  • With monitoring function downstream switching devices : No
  • Compression-resistant : No
  • Type of switch function : Breaker contact
  • Material housing : Metal
  • Coating housing : Nickel-plated
  • Type of electric connection : Connector M8
  • Explosion safety category for gas : None
  • Construction type housing : Cylinder, screw-thread
  • Type of interface for safety communication : None
  • Mechanical mounting condition for sensor : Concise
  • Explosion safety category for dust : None
  • Voltage type : DC
  • Type of interface : None
  • Category according to EN 954-1 : 1
  • Interference resistance to magnetic fields : Immune against magnetic DC-field
  • Type of switching output : PNP
  • Type of actuation : Metallic Target
  • Performance level acc. EN ISO 13849-1 : None
  • Number of semiconductor outputs with signalling function : 1
  • SIL according to IEC 61508 : None