Description
Detail
Schneider Electric ATV212WU30N4C Altivar 212 3kW variable speed drive for pumps and fans in HV AC incorporates flux vector control without sensor, standard asynchronous motor control profile. APOGEE FLN, BACnet, LonWorks, METASYS N2 and Modbus communication port protocol. 40 to 50°C with derating factor operating temperature. Conforms to 3 IEC 61800-5-1 pollution degree.
- · Current Rating: 7.2A
- · Height: 340mm
- · Range: Altivar 212
- · Width: 230mm
- · Weight: 10.55kg
- · For Use With Motor: ATV212 Asynchronous
- · Depth: 208mm
- · IP Rating: IP55
- · Supply Voltage: 380 to 480V
Specification
Supporting protocol for PROFINET CBA : No
Supporting protocol for TCP/IP : No
Supporting protocol for PROFIBUS : No
Supporting protocol for LON : Yes
Supporting protocol for SUCONET : No
Supporting protocol for Data-Highway : No
Supporting protocol for INTERBUS : No
Supporting protocol for KNX : No
Supporting protocol for MODBUS : Yes
With control unit : Yes
Supporting protocol for DeviceNet : No
Supporting protocol for other bus systems : Yes
Supporting protocol for SERCOS : No
With PC connection : Yes
Supporting protocol for ASI : No
Supporting protocol for PROFINET IO : No
Supporting protocol for Foundation Fieldbus : No
Supporting protocol for EtherNet/IP : No
Supporting protocol for INTERBUS-Safety : No
Supporting protocol for DeviceNet Safety : No
Supporting protocol for SafetyBUS p : No
Supporting protocol for PROFIsafe : No
Supporting protocol for AS-Interface Safety at Work : No
Integrated breaking resistance : No
Application in industrial area permitted : Yes
4-quadrant operation possible : No
Application in domestic- and commercial area permitted : Yes
Max. output at quadratic load at rated output voltage : 0 kW
Mains frequency : 50/60 Hz
Number of phases output : 3
Number of phases input : 3
Number of HW-interfaces other : 0
Number of interfaces PROFINET : 0
Number of HW-interfaces parallel : 0
Number of HW-interfaces RS-232 : 0
Number of HW-interfaces serial TTY : 0
Number of HW-interfaces RS-422 : 0
Number of HW-interfaces RS-485 : 1
Relative symmetric net voltage tolerance : 0 %
Type of converter : I converter
Number of HW-interfaces industrial Ethernet : 0
Degree of protection (IP) : IP55
Number of HW-interfaces USB : 0
Width : 230 mm
Height : 340 mm
Max. output voltage : 480 V
Depth : 208 mm
Max. output at linear load at rated output voltage : 3 kW
Relative symmetric net frequency tolerance : 5 %
Max. output frequency : 200 Hz
Nominal output current I2N : 7.2 A
Mains voltage : 380 – 480 V
With optical interface : No
Supporting protocol for CAN : No