Description
Detail
Schneider Electric ATV212WD55N4C Altivar 212 55kW variable speed drive for pumps and fans in HV AC incorporates flux vector control without sensor, standard asynchronous motor control profile. APOGEE FLN, BACnet, LonWorks, METASYS N2 and Modbus communication port protocol. 40 to 50°C with derating factor operating temperature. Conforms to 3 IEC 61800-5-1 pollution degree.
- · Current Rating: 116A
- · Height: 1,000mm
- · Range: Altivar 212
- · Width: 362mm
- · For Use With Motor: ATV212 Asynchronous
- · Depth: 364mm
- · IP Rating: IP55
- · Supply Voltage: 380 to 480V
Specification
Supporting protocol for SERCOS : No
Supporting protocol for DeviceNet : No
Supporting protocol for Data-Highway : No
Supporting protocol for TCP/IP : No
Supporting protocol for PROFIBUS : No
Supporting protocol for LON : Yes
Supporting protocol for KNX : No
Supporting protocol for INTERBUS : No
Supporting protocol for MODBUS : Yes
Supporting protocol for SUCONET : No
With control unit : Yes
4-quadrant operation possible : No
Supporting protocol for other bus systems : Yes
Supporting protocol for DeviceNet Safety : No
Supporting protocol for CAN : No
Supporting protocol for Foundation Fieldbus : No
Supporting protocol for PROFINET CBA : No
With PC connection : Yes
Supporting protocol for EtherNet/IP : No
Supporting protocol for AS-Interface Safety at Work : No
Supporting protocol for INTERBUS-Safety : No
Supporting protocol for PROFINET IO : No
Supporting protocol for PROFIsafe : No
Supporting protocol for SafetyBUS p : No
Application in domestic- and commercial area permitted : Yes
Application in industrial area permitted : Yes
Integrated breaking resistance : No
Number of HW-interfaces industrial Ethernet : 0
Mains frequency : 50/60 Hz
Number of phases output : 3
Number of phases input : 3
Type of converter : I converter
Number of HW-interfaces parallel : 0
Number of interfaces PROFINET : 0
Number of HW-interfaces serial TTY : 0
Number of HW-interfaces other : 0
Number of HW-interfaces RS-232 : 0
Height : 1000 mm
Relative symmetric net voltage tolerance : 0 %
Number of HW-interfaces RS-422 : 0
Number of HW-interfaces RS-485 : 1
Degree of protection (IP) : IP55
Max. output at quadratic load at rated output voltage : 0 kW
Number of HW-interfaces USB : 0
Width : 362 mm
Depth : 364 mm
Max. output frequency : 200 Hz
Nominal output current I2N : 116 A
Max. output voltage : 480 V
Max. output at linear load at rated output voltage : 55 kW
Relative symmetric net frequency tolerance : 5 %
Mains voltage : 380 – 480 V
With optical interface : No
Supporting protocol for ASI : No