Description
Detail
Schneider Electric ATV212WD55N4 Altivar 212 55kW variable speed drive for pumps and fans in HV AC incorporates flux vector control without sensor, standard asynchronous motor control profile. APOGEE FLN, BACnet, LonWorks, METASYS N2 and Modbus communication port protocol. 40 to 50°C with derating factor operating temperature. Conforms to 3 IEC 61800-5-1 pollution degree.
- · Current Rating: 116A
- · Height: 1,000mm
- · Range: Altivar 212
- · Width: 362mm
- · For Use With Motor: ATV212 Asynchronous
- · Depth: 364mm
- · IP Rating: IP55
- · Supply Voltage: 380 to 480V
Specification
Supporting protocol for PROFINET IO : No
Supporting protocol for MODBUS : Yes
Supporting protocol for KNX : No
Supporting protocol for CAN : No
Supporting protocol for INTERBUS : No
Supporting protocol for ASI : No
Supporting protocol for PROFIBUS : No
Supporting protocol for DeviceNet : No
With control unit : Yes
Supporting protocol for SERCOS : No
Supporting protocol for SUCONET : No
Supporting protocol for LON : Yes
Supporting protocol for AS-Interface Safety at Work : No
4-quadrant operation possible : No
Supporting protocol for Data-Highway : No
Supporting protocol for INTERBUS-Safety : No
Supporting protocol for DeviceNet Safety : No
Supporting protocol for other bus systems : Yes
With PC connection : Yes
Supporting protocol for PROFIsafe : No
Supporting protocol for SafetyBUS p : No
Supporting protocol for EtherNet/IP : No
Supporting protocol for Foundation Fieldbus : No
Supporting protocol for PROFINET CBA : No
Application in industrial area permitted : Yes
Integrated breaking resistance : No
Application in domestic- and commercial area permitted : Yes
Number of HW-interfaces RS-422 : 0
Number of phases output : 3
Mains frequency : 50/60 Hz
Number of phases input : 3
Type of converter : I converter
Number of interfaces PROFINET : 0
Number of HW-interfaces parallel : 0
Number of HW-interfaces other : 0
Number of HW-interfaces RS-232 : 0
Number of HW-interfaces USB : 0
Number of HW-interfaces serial TTY : 0
Height : 1000 mm
Number of HW-interfaces RS-485 : 1
Relative symmetric net voltage tolerance : 0 %
Degree of protection (IP) : IP55
Number of HW-interfaces industrial Ethernet : 0
Max. output at quadratic load at rated output voltage : 0 kW
Depth : 364 mm
Width : 362 mm
Nominal output current I2N : 116 A
Max. output frequency : 200 Hz
Max. output at linear load at rated output voltage : 55 kW
Max. output voltage : 480 V
Relative symmetric net frequency tolerance : 5 %
Mains voltage : 380 – 480 V
With optical interface : No
Supporting protocol for TCP/IP : No