Description
Detail
Schneider Electric ATV212WD18N4 Altivar 212 18.5kW variable speed drive for pumps and fans in HV AC incorporates flux vector control without sensor, standard asynchronous motor control profile. APOGEE FLN, BACnet, LonWorks, METASYS N2 and Modbus communication port protocol. 40 to 50°C with derating factor operating temperature. Conforms to 2 IEC 61800-5-1 pollution degree.
- · Current Rating: 37A
- · Height: 665mm
- · Range: Altivar 212
- · Width: 310mm
- · Weight: 37.4kg
- · For Use With Motor: ATV212 Asynchronous
- · Depth: 315mm
- · IP Rating: IP55
- · Supply Voltage: 380 to 480V
Specification
Supporting protocol for INTERBUS-Safety : No
Supporting protocol for ASI : No
Supporting protocol for PROFIBUS : No
Supporting protocol for other bus systems : Yes
Supporting protocol for TCP/IP : No
Supporting protocol for INTERBUS : No
Supporting protocol for Data-Highway : No
Supporting protocol for MODBUS : Yes
With control unit : Yes
Supporting protocol for SUCONET : No
Supporting protocol for DeviceNet : No
Supporting protocol for SERCOS : No
Supporting protocol for LON : Yes
Supporting protocol for AS-Interface Safety at Work : No
Supporting protocol for KNX : No
With PC connection : Yes
Supporting protocol for EtherNet/IP : No
Supporting protocol for PROFINET CBA : No
Supporting protocol for PROFIsafe : No
4-quadrant operation possible : No
Supporting protocol for DeviceNet Safety : No
Supporting protocol for Foundation Fieldbus : No
Application in domestic- and commercial area permitted : Yes
Supporting protocol for PROFINET IO : No
Supporting protocol for SafetyBUS p : No
Integrated breaking resistance : No
Application in industrial area permitted : Yes
Number of HW-interfaces industrial Ethernet : 0
Number of phases output : 3
Number of phases input : 3
Type of converter : I converter
Mains frequency : 50/60 Hz
Max. output at quadratic load at rated output voltage : 0 kW
Number of HW-interfaces parallel : 0
Number of HW-interfaces USB : 0
Number of HW-interfaces RS-485 : 1
Number of HW-interfaces RS-422 : 0
Number of HW-interfaces RS-232 : 0
Number of HW-interfaces serial TTY : 0
Number of interfaces PROFINET : 0
Relative symmetric net voltage tolerance : 0 %
Degree of protection (IP) : IP55
Number of HW-interfaces other : 0
Depth : 315 mm
Width : 310 mm
Nominal output current I2N : 37 A
Max. output at linear load at rated output voltage : 18.5 kW
Height : 665 mm
Max. output frequency : 200 Hz
Relative symmetric net frequency tolerance : 5 %
Max. output voltage : 480 V
Mains voltage : 380 – 480 V
With optical interface : No
Supporting protocol for CAN : No