Description
Detail
Schneider Electric ATV212W075N4C Altivar 212 0.75kW variable speed drive for pumps and fans in HV AC incorporates flux vector control without sensor, standard asynchronous motor control profile. APOGEE FLN, BACnet, LonWorks, METASYS N2 and Modbus communication port protocol. 40 to 50°C with derating factor operating temperature. Conforms to 2 IEC 61800-5-1 pollution degree.
- · Current Rating: 2.2A
- · Height: 297mm
- · Range: Altivar 212
- · Width: 215mm
- · Weight: 7.5kg
- · For Use With Motor: ATV212 Asynchronous
- · Depth: 192mm
- · IP Rating: IP55
- · Supply Voltage: 380 to 480V
Specification
Supporting protocol for DeviceNet Safety : No
Supporting protocol for ASI : No
Supporting protocol for CAN : No
Supporting protocol for Data-Highway : No
Supporting protocol for LON : Yes
Supporting protocol for SUCONET : No
Supporting protocol for INTERBUS : No
Supporting protocol for MODBUS : Yes
Supporting protocol for DeviceNet : No
Supporting protocol for KNX : No
Supporting protocol for INTERBUS-Safety : No
With control unit : Yes
4-quadrant operation possible : No
Supporting protocol for AS-Interface Safety at Work : No
With optical interface : No
Supporting protocol for EtherNet/IP : No
Supporting protocol for SERCOS : No
Supporting protocol for other bus systems : Yes
With PC connection : Yes
Supporting protocol for PROFINET IO : No
Supporting protocol for PROFIsafe : No
Application in industrial area permitted : Yes
Supporting protocol for SafetyBUS p : No
Supporting protocol for Foundation Fieldbus : No
Supporting protocol for PROFINET CBA : No
Application in domestic- and commercial area permitted : Yes
Integrated breaking resistance : No
Number of HW-interfaces industrial Ethernet : 0
Mains frequency : 50/60 Hz
Number of phases input : 3
Type of converter : I converter
Degree of protection (IP) : IP55
Number of HW-interfaces parallel : 0
Max. output at quadratic load at rated output voltage : 0 kW
Number of HW-interfaces RS-422 : 0
Number of HW-interfaces USB : 0
Number of HW-interfaces RS-232 : 0
Number of HW-interfaces RS-485 : 1
Number of HW-interfaces serial TTY : 0
Relative symmetric net voltage tolerance : 0 %
Number of interfaces PROFINET : 0
Number of phases output : 3
Number of HW-interfaces other : 0
Max. output at linear load at rated output voltage : 0.75 kW
Depth : 192 mm
Height : 297 mm
Width : 215 mm
Max. output voltage : 480 V
Nominal output current I2N : 2.2 A
Max. output frequency : 200 Hz
Relative symmetric net frequency tolerance : 5 %
Mains voltage : 380 – 480 V
Supporting protocol for TCP/IP : No
Supporting protocol for PROFIBUS : No