TeSys D contactor, 4p(2 NO+2 NC), AC-1 <= 440 V 60A, 24 V AC 50/60 Hz

£399.76 inc VAT £333.13 ex VAT

SKU: 2500150810 Category: Tags: , ,

Description

Detail

TeSys D contactor, 4p(2 NO+2 NC), AC-1 <= 440 V 60A, 24 V AC 50/60 Hz coil. range: TeSys – product name: TeSys D – product or component type: contactor – device short name: LC1D – contactor application: resistive load – utilisation category: AC-1 – poles description: 4P – pole contact composition: 2 NO + 2 NC – [Ue] rated operational voltage: <= 300 V DC for power circuit, <= 690 V AC 25…400 Hz for power circuit – overvoltage category: III – [Icw] rated short-time withstand current: 165 A <= 40 °C 1 min power circuit, 320 A <= 40 °C 10 s power circuit, 72 A <= 40 °C 10 min power circuit, 720 A <= 40 °C 1 s power circuit – associated fuse rating: 80 A gG at <= 690 V coordination type 1 for power circuit, 80 A gG at <= 690 V coordination type 2 for power circuit – [Ui] rated insulation voltage: 600 V for power circuit certifications CSA, 600 V for power circuit certifications UL, 690 V for power circuit conforming to IEC 60947-4-1 – protective cover: without – mounting support: plate, rail – standards: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508 – product certifications: BV, CCC, CSA, DNV, GL, GOST, LROS (Lloyds register of shipping), RINA, UL – connections – terminals: control circuit : screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: flexible – with cable end, control circuit : screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: flexible – without cable end, control circuit : screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: solid – without cable end, control circuit : screw clamp terminals 2 cable(s) 1…2.5 mm² – cable stiffness: flexible – with cable end, control circuit : screw clamp terminals 2 cable(s) 1…4 mm² – cable stiffness: flexible – without cable end, control circuit : screw clamp terminals 2 cable(s) 1…4 mm² – cable stiffness: solid – without cable end, power circuit : screw clamp terminals 1 cable(s) 1…35 mm² – cable stiffness: flexible – with cable end, power circuit : screw clamp terminals 1 cable(s) 1…35 mm² – cable stiffness: flexible – without cable end, power circuit : screw clamp terminals 1 cable(s) 1…35 mm² – cable stiffness: solid – without cable end, power circuit : screw clamp terminals 2 cable(s) 1…25 mm² – cable stiffness: flexible – with cable end, power circuit : screw clamp terminals 2 cable(s) 1…25 mm² – cable stiffness: flexible – without cable end, power circuit : screw clamp terminals 2 cable(s) 1…25 mm² – cable stiffness: solid – without cable end – tightening torque: control circuit : 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm, control circuit : 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2, power circuit : 5 N.m – on screw clamp terminals – cable 1…25 mm² hexagonal 4 mm, power circuit : 8 N.m – on screw clamp terminals – cable 25…35 mm² hexagonal 4 mm – operating time: 12…26 ms closing, 4…19 ms opening – safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 – mechanical durability: 6 Mcycles.

Specification

  • Type of electrical connection of main circuit : Screw connection
  • Voltage type for actuating : AC
  • Number of main contacts as normally open contact : 2
  • Number of normally closed contacts as main contact : 2
  • Number of auxiliary contacts as normally open contact : 0
  • Number of auxiliary contacts as normally closed contact : 0
  • Rated control supply voltage Us at AC 50HZ : 24 – 24 V
  • Rated control supply voltage Us at AC 60HZ : 24 – 24 V
  • Modular version : No